A 14 IOM-DPCDPR-A: FEB 2014
5.4. DPR2000GALW, Measurement ranges and metrological parameters.
5.4.1 DPR2000GALW. Measurement ranges
N
Nominal range
(FSO)
Minimum set range
Overpressure
limit
Static pressure limit
1
0...25mbar (0...2500Pa)
1mbar (100Pa)
1bar
350mbar
2
-2,5...2,5mbar (-250...250Pa)
0,2mbar (20Pa)
350mbar
350mbar
3
-7...7mbar (-700...700Pa)
1mbar (100Pa)
350mbar
350mbar
4
-25...25mbar (-2500...2500Pa)
5mbar (500Pa)
1bar
1bar
5
-100...100mbar (-10...10Pa)
20mbar (2kPa)
1bar
1bar
5.4.2. DPR2000GALW. Metrological parameters.
Nominal range
0...25mbar
-2,5...2,5mbar
-7...7mbar
-25...25mbar
-100...100mbar
Accuracy
0,075 %
0,16 %
0,1 %
0,1 %
0,075 %
Thermal error
0,1 % (FSO)/ 10C, max 0,4 % (FSO) for the whole thermal compensation
range
Thermal compensation range
-10 … 70
0
C
Additional electronic damping
0...60 s
5.4.3. DPR2000GALW. Construction materials
M20x1,5/6x1 adapter brass
Valve manifold ss316L
Valve manifold adapter ss316L
¼ NPT connector brass, ss316L or galvanized St3S carbon steel
(Other materials as given in 5.1.3 for DPR...).
5.4.4. DPR2000GALW. Pressure Connectors
- The terminals fit adapted to ø 6x1 plastic tubes,
- Valve manifold adapter or ¼ NPT connector- (see p. 8.3. and fig.17).
5.5. DPR2000YALW. Measurement ranges and metrological parameters.
5.5.1. DPR2000YALW. Measurement ranges.
5.5.2. DPR2000YALW. Metrological parameters.
* zeroing in static pressure conditions with zero differential pressure eliminate this error.
Medium density range up to 1,1 g/cm
3
(standard version)
over 1,1 g/cm
3
(special version by arrangement with DELTA CONTROLS)
N
1
2
Nominal range
0... 6000 mmH
2
O
0... 1600 mmH
2
O
Minimum set range
600 mmH
2
O
160 mmH
2
O
Static pressure limit
40 bar
Nominal range N
1
2
Accuracy for basic range
± 0,16 %
± 0,2 %
Accuracy for minimum range
± 0,5 %
± 0,6 %
temperature error
0,4 % for temperatures 25...+80°C
Zero shift error from static pressure *
0,08 % / 10bar
0,1 % / 10bar